In remote and low-touch operations, fuel is not just a cost line—it is a reliability constraint. Generator fuel planning determines how long a site can stay online through utility outages, storms, supply delays, and access restrictions. The goal is to build autonomy: the ability to operate safely and predictably for a defined period with minimal human intervention, while maintaining enough reserve to handle “unknown unknowns.”
Generator autonomy is the number of hours (or days) a site can operate on generator power before fuel becomes the limiting factor. Autonomy depends on:
• Fuel on hand (usable volume, not just tank capacity)
• Burn rate (which changes with load and temperature)
• Operational constraints (maintenance intervals, refueling access, and generator duty cycle)
In remote Arctic operations, “autonomy” should be treated as an engineered target with explicit assumptions—because access delays are a normal condition, not a rare event.
Fuel planning starts with understanding what your site actually consumes. A reliable plan separates critical load (must stay up) from non-critical load (can be shed).
Critical loads often include: core network/compute, safety systems, heating for equipment spaces, monitoring/telemetry, and minimum lighting/security.
Non-critical loads may include: comfort heating, non-essential compute, auxiliary lighting, and any equipment that can be paused without damage.
If your plan assumes you will shed load during extended outages, you need a documented and tested load-shedding procedure—otherwise it won’t happen in time.
The simplest autonomy calculation is:
Autonomy (hours) = Usable fuel (liters or gallons) ÷ Average burn rate (liters/hour or gallons/hour)
The key word is average. Burn rate changes with:
• Electrical load (kW demand)
• Generator efficiency curve (many generators burn disproportionately at very low load)
• Ambient temperature (cold starts, warmup time, and fuel viscosity effects)
• Auxiliary loads (block heaters, circulation pumps, fuel heaters, battery chargers)
If you don’t have measured data, a conservative planning approach is to compute autonomy at peak expected outage load, then add buffer on top.
Strong fuel plans define three thresholds:
Target level: the normal operating level after a delivery (what you aim to return to).
Reorder trigger: the level at which you schedule the next delivery (based on delivery lead time and risk).
Hard reserve: “do not consume” buffer held for unexpected delays, severe weather, or extended outages.
In low-touch sites, the reorder trigger should be set so that even if delivery is delayed, the site can still meet its required autonomy plus reserve. The hard reserve is what keeps a long outage from becoming a crisis.
Cold introduces failure modes that can invalidate otherwise “correct” fuel plans:
Fuel gelling and waxing: diesel behavior changes with temperature; seasonal blends and additives matter.
Water and ice contamination: condensation and poor fuel handling can create filters blocked by ice crystals.
Cold-start penalties: multiple start attempts, warmup time, and heaters can raise consumption during transitions.
Reduced battery performance: starting systems and control electronics may need extra support in low temperatures.
Autonomy planning should include the reality that extreme cold can increase burn (heaters, warmup) and can also reduce the probability of successful starts if maintenance is weak.
In remote regions, the reliability of fuel delivery is as important as fuel quantity. Planning should explicitly account for:
• Delivery routes and seasonal access: road closures, ice roads, marine delivery windows, aviation constraints.
• Vendor lead times: scheduling constraints, fleet availability, and minimum order sizes.
• Site access and safety: snow clearance, spill prevention, and transfer procedures in severe weather.
• Single points of failure: one supplier, one tank, one pump, one hose, one trained person.
If a site is truly low-touch, build contingency plans that do not assume last-minute delivery will succeed.
Remote autonomy requires visibility. At minimum, monitoring should cover:
Fuel level: continuous telemetry with sanity checks (detect stuck sensors or sudden drops).
Run hours: generator runtime tracking for maintenance intervals and autonomy forecasting.
Fuel burn rate: derived from level slope over time or from flow meters when available.
Generator health: alarms for oil pressure, coolant temp, battery voltage, and start failures.
Environmental inputs: temperature, wind, and precipitation that correlate to risk.
Alerts should be tied to thresholds that map to action: reorder trigger, reserve boundary, and “site survival” minimum.
Fuel autonomy depends on how you operate during outages. Useful playbooks include:
Generator start and transfer checklist: confirm start, stabilize, confirm transfer, confirm load, confirm alarms clear.
Extended outage mode: actions to reduce load, raise monitoring frequency, and preserve reserve.
Load-shedding procedure: pre-defined steps to drop non-critical loads safely and quickly.
Start failure escalation: structured troubleshooting, remote actions, and when to dispatch.
For Arctic sites, include explicit steps for cold-related conditions (block heater status, fuel heater checks, and “start attempt limits” to protect batteries).
Autonomy improves dramatically when you reduce consumption. Common strategies:
Right-size generator capacity: oversized generators can be inefficient at low load and can suffer from wet stacking.
Use multiple generators: staged generation lets you match capacity to load (one small unit for baseline, larger unit for peaks).
Improve load efficiency: high-efficiency power supplies, modern HVAC controls, and eliminating phantom loads.
Hybridize: batteries, solar, or wind can reduce generator runtime, especially for baseline loads and to avoid short cycling.
Run-window strategy: for some sites, powering up in scheduled windows (if service allows) can reduce total burn.
Hybrid strategies also reduce mechanical wear by lowering run hours—often improving both autonomy and maintenance intervals.
Fuel autonomy is only real if the generator reliably starts and runs under load. Best practice includes:
Regular test runs under load: not just idle tests—verify stable operation and transfer performance.
Maintenance tracking: filters, oil, coolant, belts, battery health, and starter system checks.
Fuel management: periodic sampling, water separation, polishing if needed, and tank housekeeping to prevent microbial growth and sediment buildup.
Spill prevention and containment: because a spill event can become both an outage and a compliance incident.
In remote sites, an untested generator is functionally the same as having no generator—plan your autonomy around tested capability, not nameplate expectations.
Set it based on worst-case delivery lead time plus the autonomy you must preserve. If deliveries can be delayed by weather, the reorder trigger should assume delays will happen and still keep you above reserve.
Tanks often have unusable volume (pickup height, sediment layer, safety reserve) and sensor error. Planning should use conservative usable volume to avoid surprise run-outs.
Cold-start issues and fuel problems (gelling, water contamination, clogged filters) are frequent causes—often made worse by insufficient testing under real load and weak preventive maintenance.
Yes. Batteries can handle short transients, reduce generator cycling, and allow more efficient generator operation. In some designs they also enable “quiet” periods or let you run the generator at optimal load rather than at inefficient low-load conditions.
Autonomy: How long a site can operate before fuel becomes the limiting factor.
Burn rate: Fuel consumption per hour at a given load and operating condition.
Critical load: Systems that must remain powered to maintain service and safety.
Load shedding: Turning off non-critical loads to reduce consumption and extend runtime.
Transfer switch: Equipment that shifts the site from utility power to generator power (often automatically).
Wet stacking: A condition in diesel generators running too lightly loaded, causing incomplete combustion and buildup that can reduce reliability.
Fuel polishing: Filtering and conditioning stored fuel to remove water and contaminants.